To A BAT-LTE

  • Terminal 1(TIP) should be wired to Tip on the panel (used for communication)
  • Terminal 2(RING) should be wired to Ring on the panel (used for communication)
  • Terminal 3(6-24v-POS AUX) should be wired to Pos aux on the panel 
  • Terminal 4(NEG AUX) should be wired to Neg aux on the panel
  • Terminal 5(Y IN) should be wired to the programmable output on the panel (used for interactive service)
  • Terminal 13(OC1) should be wired to any open zone on the panel (used for interactive service)
  • zone resistor (used to indicate change of state) should be placed parallel on Terminal 3 to Terminal 5 on the BAT CDMA

TIP HINT:

  • Wired as a keyswitch, you will be able to remotely Arm/Disarm the alarm panel using the mobile app.