To A BAT-CDMA-L

  • Terminal 1(RING) should be wired to Ring on the panel (used for communication)
  • Terminal 2(TIP) should be wired to Tip on the panel (used for communication)
  • Terminal 3(NEG AUX) should be wired to Neg aux on the panel 
  • Terminal 4(POS AUX) should be wired to Pos aux on the panel
  • Terminal 5(PGM) should be wired to the programmable output on the panel (used for interactive service)
  • Terminal 15(ZN) should be wired to any open zone on the panel (used for interactive service)
  • zone resistor (used to indicate change of state) should be placed parellel from Terminal 3 to Terminal 5 on the BAT CDMA L

TIP HINT:

  • Wired as a keyswitch, you will be able to remotely Arm/Disarm the alarm panel using the mobile app Securesmart or from the web portal