To A CAT-CDMA(red board)

 

  • Terminal 1(RING) should be wired to Ring on the panel (used for communication)
  • Terminal 2(TIP) should be wired to Tip on the panel (used for communication)
  • Terminal 3(NEG AUX) should be wired to Neg aux on the panel 
  • Terminal 4(POS AUX) should be wired to Pos aux on the panel
  • Terminal 5(PGM) should be wired to the programmable output on the panel (used for interactive service)
  • Terminal 8(ZN) should be wired to any open zone on the panel (used for interactive service)
  • a zone resistor (used to indicate change of state) should be placed parellel from Terminal 4 to Terminal 5 on the CAT CDMA

TIP HINT:

  • Wired as a keyswitch, you will be able to remotely Arm/Disarm the alarm panel using the mobile app Securesmart or from the web portal
Have more questions? Submit a request

2 Comments

  • 0
    Avatar
    Shay Webb

    The resistor must be 5.6k for DSC panels with a keyswitch.

  • 0
    Avatar
    Shay Webb

    Programming a keyswitch on a DSC panel:

    Field 001 Program 22
    Field 009 Program PGM 5
    Field 501 Disable 3
    Field 301 Enter receiver number
    Field 310 Enter Account Number
    Field 350 Enter 03 (Contact ID)
    Field 351 Enter 1 
    Field 359 Enter 1 
    Field 367 Enter 1,1 (O/C)
    Field 375 Enter 1
    Field 376 Enter 1
    Field 380 Enter 1 (Enables touch tone, dial tone for T/R)
    Field 381 Enter 5,6  (Automatic Report codes)
    Field 382 Enter 3 for no PC Link (5 with PC Link)