To A BAT-CDMA/WIFI

  • Terminal 1(TIP) should be wired to Tip on the alarm panel (used for communication)
  • Terminal 2(RING) should be wired to Ring on the alarm panel (used for communication)
  • Terminal 3(POS AUX) should be wired to Pos aux on the alarm panel 
  • Terminal 4(NEG AUX) should be wired to Neg aux on the alarm panel
  • Terminal 5(Y/TX) should be wired to the Yellow terminal on the alarm panel (used for interactive service)
  • Terminal 6(G/RX) should be wired to the Green terminal on the alarm panel (used for interactive service)

TIP HINT:


Fully supported panels will have full virtual keypad access to control their alarm system on their smartphone using the mobile app or logging into www.alarmdealer.com